A: Set P02 to a lower cycle time (e.g., 5 minutes) and ensure the thermostat is not near drafts or sunlight.
Remember: If you encounter persistent error codes or heating that won't turn on/off despite following this manual, consult a qualified HVAC technician. The Eberle Instat 6 is reliable, but system integration issues can sometimes arise. This article is for informational purposes only. Always refer to the original manufacturer’s documentation for safety-critical steps. eberle instat 6 user manual english
| Button | Symbol | Function | |--------|--------|----------| | 1 | Up arrow (▲) | Increase temperature / navigate menu up | | 2 | Down arrow (▼) | Decrease temperature / navigate menu down | | 3 | Clock (🕘) | Enter programming / time settings / confirm | | 4 | Auto/Manual (👤) | Switch between Auto (schedule) and Manual (permanent hold) | | 5 | On/Off (⏻) | Power / standby (frost protection remains active) | A: Set P02 to a lower cycle time (e
| Terminal | Label | Description | |----------|-------|-------------| | N | Neutral (mains input) | 230V AC neutral | | L | Live (mains input) | 230V AC live | | 1 | Common (COM) | Relay common contact | | 2 | Normally Open (NO) | Relay NO – closes on heat call | | 3 | Normally Closed (NC) | Not used in most heating systems | | (S1, S2) | External sensor | Optional floor sensor (if equipped) | This article is for informational purposes only
| Parameter | Description | Range | Default | Typical setting | |-----------|-------------|-------|---------|------------------| | P01 | Temperature control type | 0=ON/OFF, 1=PID | 0 | 1 for underfloor heating, 0 for radiators | | P02 | Cycle time (minutes) – only for ON/OFF | 1-30 | 10 | 5 for gas boiler, 15 for electric | | P03 | Minimum setpoint limit | 5-15°C | 5 | 10 (to prevent excessive cooling) | | P04 | Maximum setpoint limit | 20-35°C | 30 | 27 | | P05 | Frost protection temperature | 5-15°C | 7 | 7 | | P06 | Open window detection sensitivity | 0=off, 1-3 (1=low) | 2 | 1 if room has frequent drafts | | P07 | Display brightness | 1-5 | 3 | 2 | | P08 | Sensor calibration offset | -3 to +3°C | 0 | Use if measured temp differs |
Last Updated: May 2026 Product Focus: Eberle Instat 6 Electronic Room Thermostat